Chlamydia Trachomatis, Ureaplasma urealyticum na mycoplasma genitalium

Ibisobanuro bigufi:

Iki gikoresho kigenewe muri vitro yujuje ubuziranenge bwa Chlamydia trachomatis (CT), Ureaplasma urealyticum (UU), na Mycoplasma genitalium (MG) mu gitsina cy’abagabo, inkondo y'umura y’abagore, hamwe n’icyitegererezo cy’abagore, kandi gitanga ubufasha mu gusuzuma no kuvura abarwayi bafite indwara zandurira mu mibonano mpuzabitsina.


Ibicuruzwa birambuye

Ibicuruzwa

Izina ryibicuruzwa

HWTS-UR043-Chlamydia Trachomatis, Ureaplasma urealyticum na Mycoplasma genitalium Nucleic Acide Detection Kit

Epidemiologiya

Chlamydia trachomatis (CT) ni ubwoko bwa mikorobe ya prokaryyotike yangiza cyane mu ngirabuzimafatizo za eukaryotic. Chlamydia trachomatis igabanijwemo AK serotypes ukurikije uburyo bwa serotype. Indwara ya Urogenital iterwa ahanini na trachoma biologiya variant DK serotypes, kandi igitsina gabo kigaragara cyane nka urethritis, gishobora koroherwa nta kwivuza, ariko inyinshi murizo ziba karande, zikiyongera, kandi zishobora guhuzwa na epididymitis, proctite, nibindi. Ureaplasma urealyticum (UU) ni mikorobe ntoya ya prokaryotic ishobora kubaho yigenga hagati ya bagiteri na virusi, kandi ni na mikorobe itera indwara ikunda kwandura imyanya ndangagitsina n'inkari. Ku bagabo, irashobora gutera prostatite, urethritis, pyelonephritis, n'ibindi. Ku bagore, irashobora gutera reaction mu myororokere nka vaginitis, cervicitis, n'indwara ya pelvic inflammatory. Nimwe mubitera gutera ubugumba no gukuramo inda. Mycoplasma genitalium (MG) ningorabahizi cyane guhinga, gukura buhoro buhoro indwara yandurira mu mibonano mpuzabitsina, kandi ni ubwoko buto bwa mycoplasma [1]. Uburebure bwa genome ni 580bp gusa. Mycoplasma genitalium ni indwara yandurira mu mibonano mpuzabitsina itera indwara zandurira mu myororokere nka urethritis itari gonococcal na epididymitis ku bagabo, cervicitis n'indwara ya pelvic inflammatory ku bagore, kandi ifitanye isano no gukuramo inda bidatinze no kubyara imburagihe.

Ibipimo bya tekiniki

Ububiko

-18 ℃

Ubuzima bwa Shelf Amezi 12
Ubwoko bw'icyitegererezo abagabo urethral swab, swab cervical swab, igitsina gore
Ct ≤38
CV < 5.0%
LoD 400Copi / μL
Ibikoresho bikoreshwa Bikenewe kugirango wandike I detection reagent:

Ikoreshwa rya Biosystems 7500-Igihe-PCR Sisitemu,

QuantStudio®5 Sisitemu nyayo-PCR, 

SLAN-96P Sisitemu nyayo-PCR Sisitemu (Hongshi Medical Technology Co., Ltd.),

LineGene 9600 Yongeyeho Sisitemu Yigihe-PCR yo Kumenya (FQD-96A, Bioertechnology ya Hangzhou),

MA-6000 Igihe Cyuzuye Cyumubyigano Wumukino (Suzhou Molarray Co., Ltd.),

BioRad CFX96 Sisitemu nyayo-PCR Sisitemu,

BioRad CFX Opus 96 Sisitemu nyayo-PCR.

Birakoreshwa mubwoko bwa II bwo gutahura reagent:

EudemonTMAIO800 (HWTS-EQ007) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Urujya n'uruza rw'akazi

Macro & Micro-Ikizamini cya virusi ADN / RNA Kit (HWTS-3017) (ishobora gukoreshwa na Macro & Micro-Test Automatic Nucleic Acide Extractor (HWTS-3006C, HWTS-3006B)), na Macro & Micro-Test Virus ADN / RNA Kit (HWTS-3017-8) (ishobora gukoreshwa na Eudemon.TM AIO800 (HWTS-EQ007)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ingano yicyitegererezo yakuweho ni 200μL naho ingano yo gusabwa ni 150μL.


  • Mbere:
  • Ibikurikira: