Virusi Yumuriro wa Hemorrhagic

Ibisobanuro bigufi:

Iki gikoresho gifasha kumenya neza virusi ya nucleic aside ya Sinema yo mu Bushinwa mu maraso ya serumu y’abakekwaho kuba barwaye indwara y’amaraso ya Sinayi, kandi itanga ubufasha mu gusuzuma abarwayi bafite umuriro w’amaraso wa Sinayi.


Ibicuruzwa birambuye

Ibicuruzwa

Izina ryibicuruzwa

HWTS-FE007B / C Ubushinwa bwa Hemorrhagic Fever Virus Nucleic Acide Detection Kit (Fluorescence PCR)

Epidemiologiya

Virusi y’indwara ya hemorhagie ya Sinayi yabanje gutandukanywa n’amaraso y’abarwayi bafite umuriro wa hemorhagie mu kibaya cya Tarim, mu Bushinwa, mu Bushinwa ndetse n’amatiku akomeye yafatiwe mu karere, maze abona izina. Kugaragara kwa clinique harimo umuriro, kubabara umutwe, kuva amaraso, guhungabana hypotensive, nibindi. nibindi, na jelly-isa na edema muri retroperitoneum.

Umuyoboro

FAM Virusi Yumuriro wa Hemorrhagic
ROX

Igenzura ryimbere

Ibipimo bya tekiniki

Ububiko

≤-18 ℃

Ubuzima bwa Shelf Amezi 9
Ubwoko bw'icyitegererezo serumu nshya
Tt ≤38
CV 5.0%
LoD 1000Copi / mL
Umwihariko

Nta reaction-reaction hamwe nizindi ngero zubuhumekero nka Grippe A, Grippe B, Legionella pneumophila, Rickettsia Q fever, Chlamydia pneumoniae, Adenovirus, virusi yubuhumekero, Parainfluenza 1, 2, 3, virusi ya Coxsackie, Echo virusi, Metapneum2 virusi A / B, Coronavirus 229E / NL63 / HKU1 / OC43, Rhinovirus A / B / C, virusi ya Boca 1/2/3/4, Chlamydia trachomatis, adenovirus, nibindi na ADN ya ADN.

Ibikoresho bikoreshwa Ikoreshwa rya Biosystems 7500-Igihe-PCR Sisitemu,

Ikoreshwa rya Biosystems 7500 Byihuse-Igihe-Sisitemu ya PCR

QuantStudio®5 Sisitemu nyayo-PCR

SLAN-96P Sisitemu nyayo-PCR

Umucyo®480 Sisitemu nyayo-PCR

LineGene 9600 Yongeyeho Sisitemu-Igihe Cyuzuye PCR

MA-6000-Igihe-Cyuzuye Cyumubare Wubushyuhe

BioRad CFX96 Sisitemu-Igihe Cyuzuye PCR

BioRad CFX Opus 96 Sisitemu nyayo-PCR

Urujya n'uruza rw'akazi

Gusabwa gukuramo reagent: Macro & Micro-Test Virus ADN / RNA Kit (HWTS-3017) (ishobora gukoreshwa na Macro & Micro-Test Automatic Nucleic Acide Extractor (HWTS-EQ011)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Icyitegererezo cyakuweho ni 200µL, naho icyifuzo cyo gukuraho ni 80µL.

Gusabwa gukuramo reagent: QIAamp Viral RNA Mini Kit (52904) na QIAGEN hamwe na Acide Nucleic Acide cyangwa Isukura Reagent (YDP315-R). Gukuramo bigomba gukorwa hakurikijwe amabwiriza yo gukoresha. Ingano yakuweho ni 140µL, naho ingano yo gusabwa ni 60µL.


  • Mbere:
  • Ibikurikira:

  • Andika ubutumwa bwawe hano hanyuma utwohereze