Umuntu CYP2C9 na VKORC1 Gene Polymorphism
Izina RY'IGICURUZWA
HWTS-GE014A-Umuntu CYP2C9 na VKORC1 Gene Polymorphism Detection Kit (Fluorescence PCR)
Icyemezo
CE / TFDA
Epidemiologiya
Warfarin ni anticoagulant yo mu kanwa ikunze gukoreshwa mubikorwa byubuvuzi muri iki gihe, igamije ahanini gukumira no kuvura indwara ziterwa na tromboembolique.Nyamara, warfarin ifite idirishya rito ryo kuvura kandi iratandukanye cyane mumoko atandukanye.Imibare yerekanye ko itandukaniro ryimiti ihamye mubantu batandukanye rishobora kuba inshuro zirenga 20.Amaraso mabi aturuka ku 15.2% by'abarwayi bafata warfarin buri mwaka, muri bo 3,5% bakagira amaraso yica.Ubushakashatsi bwa Pharmacogenomic bwerekanye ko polymorphism genetique ya enzyme yintego VKORC1 na enzyme ya metabolike CYP2C9 ya warfarin ari ikintu cyingenzi kigira ingaruka ku itandukaniro ryimiti ya warfarin.Warfarin ni ikintu cyihariye cya vitamine K epoxide reductase (VKORC1), bityo ikabuza guhuza ibintu byangiza umubiri birimo vitamine K kandi igatanga anticoagulation.Umubare munini wubushakashatsi wagaragaje ko gene polymorphism ya porotokoro ya VKORC1 aricyo kintu cyingenzi kigira ingaruka kumoko no gutandukana kwabantu kugipimo gikenewe cya warfarin.Warfarin ikoreshwa na CYP2C9, kandi ihinduka ryayo ritinda cyane metabolism ya warfarin.Abantu bakoresha warfarin bafite ibyago byinshi (inshuro ebyiri kugeza kuri eshatu hejuru) yo kuva amaraso mugihe cyambere cyo kuyakoresha.
Umuyoboro
FAM | VKORC1 (-1639G> A) |
CY5 | CYP2C9 * 3 |
VIC / HEX | IC |
Ibipimo bya tekiniki
Ububiko | Amazi: ≤-18 ℃ |
Ubuzima bwa Shelf | Amezi 12 |
Ubwoko bw'icyitegererezo | Amaraso mashya ya EDTA anticoagulated |
CV | ≤5.0% |
LoD | 1.0ng / μL |
Umwihariko | Nta re-reactivité hamwe nizindi nzego zikurikiranye cyane za genomuntu (gene ya muntu CYP2C19, gene ya muntu RPN2);mutation ya CYP2C9 * 13 na VKORC1 (3730G> A) hanze yurwego rwo kumenya iki gikoresho |
Ibikoresho bikoreshwa | Ikoreshwa rya Biosystems 7500 Sisitemu-Igihe nyacyo PCR Ikoreshwa rya Biosystems 7500 Byihuse-Igihe-Sisitemu ya PCR QuantStudio®5 Sisitemu-Igihe nyacyo PCR SLAN-96P Sisitemu nyayo-PCR UmucyoCycler®480 Sisitemu nyayo-PCR LineGene 9600 Yongeyeho Sisitemu-Igihe Cyuzuye PCR MA-6000-Igihe-Cyuzuye Cyumubare Wubushyuhe BioRad CFX96 Sisitemu-Igihe Cyuzuye PCR BioRad CFX Opus 96 Sisitemu Yigihe-PCR |
Urujya n'uruza rw'akazi
Gusabwa gukuramo reagent: Macro & Micro-Ikizamini cya virusi ADN / RNA Kit (HWTS-3001, HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) na Macro & Micro-Test Automatic Nucleic Acide (HWTS- 3006).