Aside ya Nucleic ya Ureaplasma Parvum

Ibisobanuro bigufi:

Iyi mashini ikwiriye mu gupima neza Ureaplasma Parvum (UP) mu buryo bw’isuku y’inkari z’abagabo n’iz’abagore, kandi ifasha mu gusuzuma no kuvura abarwayi banduye Ureaplasma parvum.


Ibisobanuro birambuye ku gicuruzwa

Ibirango by'ibicuruzwa

Izina ry'igicuruzwa

HWTS-UR046-Ureaplasma Parvum Nucleic Acid Detection Kit (Fluorescence PCR)

Ubumenyi bw'indwara

Ubwoko bwa Ureaplasma bufitanye isano n’indwara z’abantu bugabanyijemo amatsinda 2 ya biotypes na serotypes 14. Biogroup Ⅰ ni Ureaplasma urealyticum, irimo serotypes: 2, 4, 5, 7, 8, 9, 10, 11, 12, na 13. Biogroup Ⅱ ni Ureaplasma parvum, irimo serotypes: 1, 3, 6, 14. Ureaplasma ni udukoko dusanzwe cyangwa commensal mu myanya ndangagitsina y’abagore yo hasi kandi ni imwe mu mikorobe ikomeye itera indwara zandura mu myanya ndangagitsina. Uretse gutera indwara mu myanya ndangagitsina, abagore bafite ubwandu bwa Ureaplasma nabo bashobora kwanduza iyo ndwara abo bashakanye. Ubwandu bwa Ureaplasma nabwo ni imwe mu mpamvu zikomeye zitera ubugumba. Iyo abagore batwite banduye Ureaplasma, bishobora no gutuma ibice by'umubiri bicika imburagihe, kubyara imburagihe, indwara yo guhumeka kw'abana bato, kwandura nyuma yo kubyara n'izindi ngaruka mbi zo gutwita, zigomba kwitabwaho cyane.

Ibipimo bya tekiniki

Ububiko

-18℃

Igihe cyo kumara Amezi 12
Ubwoko bw'ingero Udukingirizo tw'inkari z'abagabo, utw'imyororokere tw'abagore
Ct ≤38
CV <5.0%
LoD Kopi 400/mL
Ibikoresho Bikoreshwa Ikoreshwa kuri reagent yo gutahura ubwoko bwa I:

Porogaramu za mudasobwa zikoreshwa mu buryo bwa "Real-Time PCR Systems",

QuantStudio®Sisitemu 5 za PCR zikora mu gihe nyacyo,

Sisitemu za PCR za SLAN-96P mu gihe nyacyo (Hongshi Medical Technology Co., Ltd.),

Sisitemu zo Gupima za LineGene 9600 Plus mu gihe nyacyo (FQD-96A, ikoranabuhanga rya Hangzhou Bioer),

MA-6000 Real-Time Quantitative Thermocycler (Suzhou Molarray Co., Ltd.),

Sisitemu ya BioRad CFX96 ya PCR mu gihe nyacyo,

Sisitemu ya BioRad CFX Opus 96 ya PCR mu gihe nyacyo.

Ikoreshwa ku gikoresho cyo gutahura ubwoko bwa II:

EudemonTMAIO800 (HWTS-EQ007) yakozwe na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Urugendo rw'akazi

Kit ya Macro & Micro-Test Viral DNA/RNA (HWTS-3017) (ishobora gukoreshwa hamwe na Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), na Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (ishobora gukoreshwa hamwe na EudemonTM AIO800 (HWTS-EQ007)) yakozwe na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ingano y'icyitegererezo cyakuwemo ni 200μL naho ingano y'icyitegererezo cyo kuyikuraho ni 150μL.


  • Ibanjirije iyi:
  • Ibikurikira:

  • Andika ubutumwa bwawe hano hanyuma ubwoherereze