Mycoplasma Hominis Acide Nucleic
Izina ry'igicuruzwa
HWTS-UR004A-Mycoplasma Hominis Nucleic Acid Detection Kit (Fluorescence PCR)
Ubumenyi bw'indwara
Indwara zandurira mu mibonano mpuzabitsina (STDs) ziracyari zimwe mu ngingo zikomeye ku mutekano w’ubuzima rusange ku isi, zishobora gutera ubugumba, kubyara umwana utarageza igihe, kubyara kanseri ndetse n’izindi ngorane zikomeye. Mycoplasma hominis iboneka mu nzira y’ubugimbi kandi ishobora gutera indwara zo kubyimba mu nzira y’ubugimbi. Ubwandu bwa MH mu nzira y’ubugimbi bushobora gutera indwara nka gonococcal urethritis, epididymitis, n’izindi, ndetse no ku bagore, zishobora gutera ububyimbirwe bw’imyanya myibarukiro ikwirakwira mu mura w’inkondo y’umura. Muri icyo gihe, ikibazo gikunze kugaragara cy’ubwandu bwa MH ni salpingitis, kandi umubare muto w’abarwayi bashobora kugira endometritis n’indwara zo kubyimba mu kibuno.
Umuyoboro
| FAM | Intego ya MH |
| VIC (HEX) | Igenzura ry'imbere |
Ibipimo bya tekiniki
| Ububiko | Amazi: ≤-18℃ Mu mwijima |
| Igihe cyo kumara | Amezi 12 |
| Ubwoko bw'ingero | imiyoboro y'inkari, imiyoboro y'inkondo y'umura |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | Kopi 1000/mL |
| Ubwihariye | Nta mpungenge zibaho hamwe n’izindi ndwara zandurira mu mibonano mpuzabitsina, zitari mu rwego rwo kuzimenya, kandi nta mpungenge zibaho hamwe na chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, herpes simplex virus type 1, herpes simplex virus type 2, nibindi. |
| Ibikoresho Bikoreshwa | Ishobora guhuza n'ibikoresho bya PCR bikoreshwa mu gupima urumuri biri ku isoko. Sisitemu za PCR zikoreshwa mu buryo bwihuse 7500 Sisitemu za PCR za QuantStudio®5 mu gihe nyacyo Sisitemu za PCR za SLAN-96P mu gihe nyacyo Sisitemu ya LightCycler®480 Real-Time PCR Sisitemu yo Gusuzuma PCR ya LineGene 9600 Plus mu gihe nyacyo MA-6000 Umuvuduko w'ubushyuhe mu gihe nyacyo Sisitemu ya BioRad CFX96 ya PCR mu gihe nyacyo Sisitemu ya BioRad CFX Opus 96 ya PCR mu gihe nyacyo |
Urugendo rw'akazi
Amahitamo ya 1.
Reagent isabwa gukurwamo: Reagent yo gusohora icyitegererezo cya Macro na Micro-Test (HWTS-3005-8). Gukuramo bigomba gukorwa hakurikijwe amabwiriza neza.
Amahitamo ya 2.
Reagent isabwa gukurwamo: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (ishobora gukoreshwa hamwe na Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Gukurwamo bigomba gukorwa neza hakurikijwe amabwiriza. Ingano ya elution isabwa igomba kuba 80 μL.
Amahitamo ya 3.
Reagent isabwa gukurwamo: Reagent yo gukuramo aside ya Nucleic cyangwa yo gusukura (YDP302) ya Tiangen Biotech (Beijing) Co., Ltd.. Gukuramo bigomba gukorwa hakurikijwe amabwiriza kandi ingano ya elution isabwa ni 80µL.