Herpes simplex virusi ubwoko bwa 1/2, Trichomonal vaginitis nucleic aside

Ibisobanuro bigufi:

Iki gikoresho kigenewe muri vitro yujuje ubuziranenge bwa virusi ya Herpes Simplex Virus Ubwoko bwa 1 (HSV1), Herpes Simplex Virus Type 2 (HSV2), na Trichomonal vaginitis (TV) mu gitsina cy’abagabo, inkondo y'umura y’abagore, hamwe n’icyitegererezo cy’abagore, kandi gitanga ubufasha mu gusuzuma no kuvura abarwayi bafite indwara zandurira mu mitsi.


Ibicuruzwa birambuye

Ibicuruzwa

Izina ryibicuruzwa

HWTS-UR045-Herpes simplex virusi ubwoko bwa 1/2, Trichomonal vaginitis nucleic aside detection kit (Fluorescence PCR)

Epidemiologiya

Indwara ya herpes ni indwara ikwirakwizwa mu mibonano mpuzabitsina iterwa na HSV2, yanduye cyane. Mu myaka ya vuba aha, ubwiyongere bw'imyanya ndangagitsina bwiyongereye ku buryo bugaragara, kandi kubera kwiyongera kw'imyitwarire y’imibonano mpuzabitsina ishobora guteza akaga, igipimo cyo gutahura HSV1 mu myanya ndangagitsina cyiyongereye kandi bivugwa ko kiri hejuru ya 20% -30%. Ubwandu bwa mbere bwanduye virusi ya herpes ahanini buceceka nta bimenyetso bigaragara byamavuriro usibye herpes zaho muri mucosa cyangwa uruhu rwabarwayi bake. Kubera ko herpes imyanya ndangagitsina irangwa no kumara virusi ubuzima bwawe bwose no kugaragara ko byongeye kubaho, ni ngombwa gusuzuma virusi byihuse kandi bikabuza kwanduza.

Ibipimo bya tekiniki

Ububiko

-18 ℃

Ubuzima bwa Shelf Amezi 12
Ubwoko bw'icyitegererezo abagabo urethral swab, swab cervical swab, igitsina gore
Ct ≤38
CV < 5.0%
LoD 400Amakopi / mL
Ibikoresho bikoreshwa Bikenewe kugirango wandike I detection reagent:

Ikoreshwa rya Biosystems 7500-Igihe-PCR Sisitemu,

QuantStudio®5 Sisitemu-Igihe nyacyo PCR, 

SLAN-96P Sisitemu nyayo-PCR Sisitemu (Hongshi Medical Technology Co., Ltd.),

LineGene 9600 Yongeyeho Sisitemu Yukuri-PCR Yerekana (FQD-96A, Ikoranabuhanga rya Hangzhou Bioer),

MA-6000 Igihe Cyuzuye Cyumubyigano Wumukino (Suzhou Molarray Co., Ltd.),

BioRad CFX96 Sisitemu nyayo-PCR Sisitemu,

BioRad CFX Opus 96 Sisitemu nyayo-PCR.

Birakoreshwa mubwoko bwa II bwo gutahura reagent:

EudemonTMAIO800 (HWTS-EQ007) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Urujya n'uruza rw'akazi

Macro & Micro-Ikizamini cya virusi ADN / RNA Kit (HWTS-3017) (ishobora gukoreshwa na Macro & Micro-Test Automatic Nucleic Acide Extractor (HWTS-3006C, HWTS-3006B)), na Macro & Micro-Test Virus ADN / RNA Kit (HWTS-3017-8) (ishobora gukoreshwa na Eudemon.TM AIO800 (HWTS-EQ007)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ingano yicyitegererezo yakuweho ni 200μL naho ingano yo gusabwa ni 150μL.


  • Mbere:
  • Ibikurikira:

  • Andika ubutumwa bwawe hano hanyuma utwohereze