Virusi ya Hepatite A.
Izina RY'IGICURUZWA
HWTS-HP005 Hepatite A virusi Nucleic Acide Detection Kit (Fluorescence PCR)
Epidemiologiya
Virusi ya Hepatite A (HAV) niyo mpamvu nyamukuru itera hepatite ikaze.Iyi virusi ni virusi nziza ya RNA imwe kandi ni iy'ubwoko bwa Hepadnavirus yo mu muryango wa Picornaviridae.Virusi ya Hepatite A, yanduzwa cyane n'inzira ya fecal-umunwa, irwanya ubushyuhe, aside, hamwe na solge nyinshi, irashobora kubaho igihe kirekire mu bishishwa, amazi, ubutaka, cyangwa imyanda yo mu nyanja [1-3].Yandura mu kugira ibiryo cyangwa amazi byanduye, cyangwa byanduye biturutse ku muntu ku muntu.Ibiribwa bifitanye isano na HAV birimo osters na clam, strawberry, raspberries, blueberries, amatariki, imboga rwatsi rwatsi, ninyanya zumye zumye [4‒6].
Umuyoboro
FAM | HAV nucleic aside |
ROX | Igenzura ryimbere |
Ibipimo bya tekiniki
Ububiko | ≤-18 ℃ |
Ubuzima bwa Shelf | Amazi: amezi 9, Lyofilize: amezi 12 |
Ubwoko bw'icyitegererezo | Serumu / intebe |
Tt | ≤38 |
CV | ≤5.0% |
LoD | Amakopi 2 / μL |
Umwihariko | Koresha ibikoresho kugirango ugerageze izindi virusi za hepatite nka hepatite B, C, D, E, enterovirus 71, virusi ya coxsackie, virusi ya Epstein-Barr, norovirus, virusi itera sida na genome ya muntu.Ntabwo habaho reaction-reaction. |
Ibikoresho bikoreshwa | Ikoreshwa rya Biosystems 7500 Sisitemu-Igihe-PCR Sisitemu Ikoreshwa rya Biosystems 7500 Byihuse-Igihe-Sisitemu ya PCR QuantStudio®5 Sisitemu nyayo-PCR SLAN-96P Sisitemu nyayo-PCR Sisitemu (Hongshi Medical Technology Co., Ltd.) UmucyoCycler®480 Sisitemu nyayo-PCR LineGene 9600 Yongeyeho Sisitemu Yigihe-PCR yo Kumenya (FQD-96A, Ikoranabuhanga rya Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler BioRad CFX96 Sisitemu-Igihe Cyuzuye PCR BioRad CFX Opus 96 Sisitemu Yigihe-PCR |
Urujya n'uruza rw'akazi
Ingero za serumu
Ihitamo 1.
Macro & Micro-Ikizamini rusange ADN / RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) na Macro & Micro-Test Automatic Nucleic Acide (HWTS-3006C, HWTS-3006B).Igomba gukururwa ukurikije amabwiriza.Ingano isabwa yo gukuraho ni 80µL.
Icya 2.
TIANamp Virus ADN / RNA Kit (YDP315-R) yakozwe na Tiangen Biotech (Beijing) Co., Ltd. Igomba gukururwa hakurikijwe amabwiriza.Ingano yicyitegererezo yakuweho ni 140μL.Ingano isabwa yo gukuraho ni 60µL.
2.Ingero z'intebe
Macro & Micro-Ikizamini rusange ADN / RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) na Macro & Micro-Test Automatic Nucleic Acide (HWTS-3006C, HWTS-3006B).Igomba gukururwa ukurikije amabwiriza.Ingano isabwa yo gukuraho ni 80µL.