Gukonjesha-Ibicurane byumye / Virusi ya grippe B Nucleic Acide
Izina ryibicuruzwa
HWTS-RT193-Gukonjesha-ibicurane byumye bya virusi / Grippe B Virus Nucleic Acide Detection Kit (Fluorescence PCR)
Epidemiologiya
Ukurikije itandukaniro rya antigenic riri hagati ya gen na NP na M, virusi yibicurane irashobora kugabanywamo amoko ane: virusi ya grippe A (IFV A), virusi ya grippe B (IFV B), virusi ya grippe C (IFV C) na virusi D (IFV D). Kuri virusi ya grippe A, ifite hosties nyinshi hamwe na serotipike igoye, kandi irashobora gukwirakwira hose binyuze mubwoko bwa genoside hamwe na mutation ihinduka. Abantu badafite ubudahangarwa burambye kuri virusi ya grippe A, bityo abantu bo mumyaka yose bakunze kwibasirwa. Virusi ya grippe A nindwara zikomeye zitera ibicurane. Kuri virusi ya grippe B, ikwirakwira ahantu hato kandi kuri ubu nta subtypes ifite. Indwara zabantu ziterwa ahanini na virusi yibicurane bya B / Yamagata cyangwa B / Victoria. Mu banduye ibicurane buri kwezi mu bihugu 15 byo mu karere ka Aziya-Pasifika, igipimo cyo gusuzuma virusi ya grippe B kiri hagati ya 0 na 92%. Bitandukanye na virusi ya grippe A, amatsinda amwe y'abantu, nk'abana ndetse n'abageze mu za bukuru, ashobora kwandura virusi ya grippe B, ishobora gutera ibibazo byoroshye, bikanateza imitwaro myinshi muri sosiyete kuruta virusi ya grippe A.
Ibipimo bya tekiniki
Ububiko | 2-28℃ |
Ubuzima bwa Shelf | Amezi 12 |
Ubwoko bw'icyitegererezo | Umuhogo |
Ct | IFV A.,IFVB Ct≤35 |
CV | <5.0% |
LoD | Amakopi 200 / mL |
Umwihariko | Kwambukiranya ibintu: Nta reaktivi iri hagati ya kit na Bocavirus, Rhinovirus, Cytomegalovirus, virusi ya syncytial respiratory, virusi ya Parainfluenza, virusi ya Epstein-Barr, virusi ya herpes simplex, virusi ya varicella-zoster, virusi ya Mumps, Enterovirus, virusi ya corona, virusi ya coronaovirus SARS-CoV, MERS-CoV, Rotavirus, Norovirus, Chlamydia pneumoniae, Mycoplasma pneumoniae, Streptococcus pneumoniae, Klebsiella pneumoniae, Streptococcus pyogenes, Legionella, Pneumocystis jirovecii, Haemophil Staphylococcus aureus, Mycobacterium igituntu, Neisseria gonorrhoeae, Candida albicans, Candida glabrata, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivarius, Moraxella catarrhalis, Lactobacillus, Lactobacillus, Cory. Ikizamini cyo kwivanga: Mucin (60mg / mL), amaraso yumuntu (50%), Phenylephrine (2 mg / mL), Oxymetazoline (2mg / mL), Sodium chloride (20mg / mL) hamwe na 5% birinda, Beclomethasone (20mg / mL), Dexamethasone (20mg / mL), Flunisolide (20mg / mL), Budesonide (1mg / mL), Mometasone (2mg / mL), Fluticasone (2mg / mL), Histamine hydrochloride (5 mg / mL), Benzocaine (10%), Menthol (10%), Zanamivir (20mg / mL), Peramivir (1mg / mL), Mupirocin (20mg / mL) . |
Ibikoresho bikoreshwa | Birakoreshwa mubwoko bwa I ikizamini reagent: Ikoreshwa rya Biosystems 7500-Igihe-PCR Sisitemu, SLAN-96P Sisitemu nyayo-PCR (Hongshi Medical Technology Co., Ltd.). Bikoreshwa muburyo bwa II ikizamini reagent: EudemonTM AIO800 (HWTS-EQ007) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Urujya n'uruza rw'akazi
PCR isanzwe
Macro & Micro-Ikizamini rusange ADN / RNA Kit (HWTS-3019) (ishobora gukoreshwa na Macro & Micro-Test Automatic Nucleic Acide Extractor (HWTS-3006C, (HWTS-3006B) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. irasabwa gukuramo icyitegererezo kandi intambwe ikurikira igomba gukorwa muburyo bukurikira IFU.
AIO800 imashini-imwe-imwe