Ubwoko 28 bwa Virusi ya Papilloma y'Umuntu (Type 16/18) ya aside nucleic

Ibisobanuro bigufi:

Iyi mashini ikwiriye mu gupima ubwoko 28 bwa virusi za papilloma z’abantu (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) mu nkari z’abagabo n’abagore ndetse n’uturemangingo tw’inkondo y’umura tw’abagore. HPV 16/18 ishobora gupimwa, ubwoko busigaye ntibushobora gupimwa burundu, butanga uburyo bw’inyongera bwo gusuzuma no kuvura ubwandu bwa HPV.


Ibisobanuro birambuye ku gicuruzwa

Ibirango by'ibicuruzwa

Izina ry'igicuruzwa

HWTS-CC006A-28 Ubwoko bwa Virusi ya Papilloma y'Umuntu ifite ibyago byinshi (Typing 16/18) Kit yo Gupima Acide Nucleic (Fluorescence PCR)

Ubumenyi bw'indwara

Kanseri y'inkondo y'umura ni imwe mu ndwara zikunze kugaragara mu myanya myibarukiro y'abagore. Ubushakashatsi bwagaragaje ko kwandura HPV guhoraho n'indwara nyinshi ari imwe mu mpamvu zikomeye zitera kanseri y'inkondo y'umura. Kuri ubu, uburyo buzwi bwo kuvura kanseri y'inkondo y'umura buracyari buke, bityo kuvumbura no gukumira ubwandu bw'inkondo y'umura buterwa na HPV ni ingenzi mu gukumira kanseri y'inkondo y'umura. Ni ingenzi cyane gushyiraho ikizamini cyoroshye, cyihariye kandi cyihuse cyo gusuzuma indwara kugira ngo hamenyekane kandi havurwe kanseri y'inkondo y'umura.

Umuyoboro

Uruvange rw'ibisubizo Umuyoboro Ubwoko
PCR-Mix1 FAM 18
VIC (HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Igenzura ry'imbere
PCR-Mix2 FAM 6, 11, 54, 83
VIC (HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Igenzura ry'imbere

Ibipimo bya tekiniki

Ububiko Amazi: ≤-18℃
Igihe cyo kumara Amezi 12
Ubwoko bw'ingero Igitambaro cyo mu nda, Igitambaro cyo mu gitsina, Inkari
Ct ≤28
CV <5.0%
LoD Kopi 300/mL
Ibikoresho Bikoreshwa Sisitemu za PCR zikoreshwa mu gihe nyacyo 7500
Sisitemu za PCR zikoreshwa mu buryo bwihuse 7500
QuantStudio®Sisitemu 5 za PCR mu gihe nyacyo
Sisitemu za PCR za SLAN-96P mu gihe nyacyo
LightCycler®Sisitemu ya PCR ya 480 mu gihe nyacyo
Sisitemu yo Gusuzuma PCR ya LineGene 9600 Plus mu gihe nyacyo
MA-6000 Umuvuduko w'ubushyuhe mu gihe nyacyo
Sisitemu ya BioRad CFX96 ya PCR mu gihe nyacyo
Sisitemu ya BioRad CFX Opus 96 ya PCR mu gihe nyacyo

Urugendo rw'akazi

Reagent isabwa gukurwamo: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (ishobora gukoreshwa hamwe na Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ongeraho 200μL y'umunyu usanzwe kugira ngo wongere ushyiremo agace gato mu ntambwe ya 2.1, hanyuma gukurwamo bigomba gukorwa hakurikijwe amabwiriza yo gukoresha iyi reagent isabwa gukurwamo. Ingano ya elution isabwa ni 80μL.
Reagent yo gukuramo isabwa: QIAamp DNA Mini Kit (51304) cyangwa Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). Ongeraho 200μL y'umunyu usanzwe kugira ngo wongere ushyiremo agace gato mu ntambwe ya 2.1, hanyuma gukuramo bigomba gukorwa hakurikijwe amabwiriza yo gukoresha iyi reagent yo gukuramo. Ingano y'icyitegererezo cyakuwemo ni 200μL, kandi ingano y'icyitegererezo cyatanzwe ni 100μL.


  • Ibanjirije iyi:
  • Ibikurikira:

  • Andika ubutumwa bwawe hano hanyuma ubwoherereze