Ubwoko 11 Ubwoko bwa Powege

Ibisobanuro bigufi:

Iyi kin ikoreshwa mu kumenya ibyuma bya Vitro Patpiratle isanzwe muri Sputom ya muntu, harimo na Haamofilic (PSE), Klebiella Pneumoniyai (KPN), Stenotrophomonas Maltophilia (Smet), Bordetella Pertussis (BP), CHLAMPLASMA PNEOniae (BPN), MyComyla Pneumoniyaila (Ukuguru). Ibisubizo birashobora gukoreshwa nkimfashanyo mu gusuzuma mu bitaro cyangwa abarwayi barembye cyane bakekwaho icyaha cya bagiteri.Iyi kin ikoreshwa mu kumenya ibyuma bya Vitro Patpiratle isanzwe muri Sputom ya muntu, harimo na Haamofilic (PSE), Klebiella Pneumoniyai (KPN), Stenotrophomonas Maltophilia (Smet), Bordetella Pertussis (BP), CHLAMPLASMA PNEOniae (BPN), MyComyla Pneumoniyaila (Ukuguru). Ibisubizo birashobora gukoreshwa nkimfashanyo mu gusuzuma mu bitaro cyangwa abarwayi barembye cyane bakekwaho icyaha cya bagiteri.


Ibisobanuro birambuye

Ibicuruzwa

Izina ry'ibicuruzwa

Hwts-rt162a 11 Ubwoko bwa Respiraratory Pathogen Nucleic Necleic Kumenya(Fluorescence PCR)

Umuyoboro

靶标 Umuyoboro
A 核酸反应液 B. 核酸反应液 c 核酸反应液 D.
HI Smet MP Ukuguru Umuryango
SP PA Bp / Cy5
Kpn Aba BPP Cpn Rox
内参 内参 内参 内参 Vic / Hex

Epidemiology

Indwara zubuhumekero nicyiciro cyingenzi cyindwara zibangamira ubuzima bwabantu, kandi ubushakashatsi bwerekanye ko indwara nyinshi zubuhumekero ziterwa na bagiteri kandi cyangwa virusi zifatanije na bagiteri, bigatuma uburemere bwindwara ndetse Urupfu, bityo usobanura rero Pathogen yemerera kwivuza no kunoza igipimo cyo kubaho[1,2].

Tekinike

Ububiko

≤-18 ℃

Imibereho-Ubuzima Amezi 12
Ubwoko bw'ikigereranyo Sputum
Ct Muraho, SP, KPN, P, Aba, Smet: CT≤33BP, BPP, MPN, CPN, Ukuguru: CT≤38
CV <5.0%
Lod KlebSella Pneumoniyae, Streptococccus PNneumoniyae, Haemophilus Grippenae, PseudomonasAeruginosa, Acinetbacter Baumannii, StenoTrophomonas Maltophilia na LegionellaPnemophila: 1000 cfu / ml;

Bordetella Pertussis na bacillustis Parapertussis: 500 cfu / ml;

Mycoplasma pneumoniae na Chlamydia pneumoniae: Kopi / ML.

Umwihariko Ibisubizo by'ibizamini byambukiranya byagaragaje ko nta byambu byambukiranya ibi bit na Cytomegalovirus, Herpesi ShoftX , Moraxella Nejenia Meningitidis, Neisryasia Meningitidis, Neisryasidididis yo muri Mycobacterium, Pseudombodidis Aruberculose, Staphylocococis Aureus, Strophylococcus, Streptococccus, Streptococccus, Acinetpopter Bacumannii, Acinetrophomonane Maltophilia, BurkrieIa Cepacia, MarnebaCerium Gerdatum, Norcarkiya, MarTrobilnes, Streegillstis, StperGoctous Spevus, StperGoctoCOCCUS ORSI PNToniaE, Chlamydia Psittaci, Coxiella Burneii na acide ya buri muntu wabantu.
Ibikoresho bisabwa Gushyira mu bikorwa biosystems 7500 igihe cya sisitemu ya PCR

Gushyira mu bikorwa biosystems 7500 byihuse-sisitemu ya PCR

Umutobe®5-igihe nyacyo PCR sisitemu

Scan-96p sisitemu nyayo pcr sisitemu

Umucyo®480 nyamara-sisitemu ya PCR

Linegene 9600 wongeyeho sisitemu nyayo ya PCR

Ma-6000 nyayo-nyayo

Biorad CFX96 Igihe cya PCR

Biorad CFX OPUS 96 Igihe cya PCR

Akazi

Macro & Micro-Ikizamini Rusange ADN / RNA Kit (HWTS-3019) Co., Ltd. Ongeraho 200μl yaphysiologiqueUmunyu kugeza mpitanya neza, kandi intambwe nyuma igomba gukorwa hakurikijwe amabwiriza. Umubumbe wabisabwa usabwe ni 100 μl.


  • Mbere:
  • Ibikurikira:

  • Andika ubutumwa bwawe hano hanyuma utwohereze