Ubwoko 11 bw'indwara zitera guhumeka
Izina ry'igicuruzwa
HWTS-RT162A Ubwoko 11 bw'ibikoresho byo gupima aside nucleic itera indwara zo mu myanya y'ubuhumekero(Fluorescence PCR)
Umuyoboro
| 靶标 | Umuyoboro | |||
| 核酸反应液 A. | 核酸反应液 B. | 核酸反应液 C. | 核酸反应液 D. | |
| HI | Smet | MP | Ukuguru | FAM |
| SP | PA | Bp | / | CY5 |
| KPN | ABA | Bpp | Cpn | ROX |
| 内参 | 内参 | 内参 | 内参 | VIC/HEX |
Ubumenyi bw'indwara
Indwara zo mu myanya y'ubuhumekero ni ubwoko bw'indwara zikomeye zibangamira ubuzima bw'abantu, kandi ubushakashatsi bwagaragaje ko indwara nyinshi zo mu myanya y'ubuhumekero ziterwa na bagiteri cyangwa virusi zitera indwara zifatanya n'umuntu, bigatuma indwara irushaho gukomera ndetse n'urupfu, bityo gusobanura neza indwara bituma umurwayi avurwa neza kandi bikongera ubuzima bwe.[1,2].
Ibipimo bya tekiniki
| Ububiko | ≤-18℃ |
| Igihe cyo kumara | Amezi 12 |
| Ubwoko bw'ingero | Amasohoro |
| Ct | HI、SP、KPN、PA、ABA、Smet:Ct≤33BP、Bpp、MP、Cpn、Ukuguru:Ct≤38 |
| CV | <5.0% |
| LoD | Klebsiella pneumoniae, Streptococcus pneumoniae, ibicurane bya Haemophilus, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia na Legionellapneumophila: 1000 CFU/mL; Bordetella pertussis na Bacillus parapertussis: 500 CFU/mL; Mycoplasma pneumoniae na Chlamydia pneumoniae: kopi 200/mL. |
| Ubwihariye | Ibisubizo by'ibizamini bya "cross-reactivity" byagaragaje ko nta "cross-reaction" yagaragaye hagati y'iyi kit na Cytomegalovirus, virusi ya Herpes simplex type 1, virusi ya Varicella-zoster, virusi ya Epstein-Barr, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella pneumophila, Moraxella catarrhalis, ubwoko bwa Mycobacterium tuberculosis bwagabanutse, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Chlamydia psittaci, Coxiella burnetii na aside nucleic nucleic y'umuntu. |
| Ibikoresho Bikoreshwa | Sisitemu za PCR zikoreshwa mu gihe nyacyo 7500 Sisitemu za PCR zikoreshwa mu buryo bwihuse 7500 QuantStudio®Sisitemu 5 za PCR mu gihe nyacyo Sisitemu za PCR za SLAN-96P mu gihe nyacyo LightCycler®Sisitemu ya PCR ya 480 mu gihe nyacyo Sisitemu zo Gusuzuma za LineGene 9600 Plus mu gihe nyacyo MA-6000 Umuvuduko w'ubushyuhe mu gihe nyacyo Sisitemu ya BioRad CFX96 ya PCR mu gihe nyacyo Sisitemu ya BioRad CFX Opus 96 ya PCR mu gihe nyacyo |
Urugendo rw'akazi
Kit ya Macro & Micro-Test General ADN/RNA (HWTS-3019) (ishobora gukoreshwa hamwe na Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) yakozwe na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ongeraho 200µL yaiy'umubiriumunyu ugera ku musemburo watunganyijwe, kandi intambwe zikurikira zigomba gukorwa hakurikijwe amabwiriza. Ingano ya elution isabwa ni 100 µL.